Troubleshooting Guide – Calomax 5 & 10 Litre Boiler

If your Calomax Eclipse boiler has the service light illuminated at the front, it may need an aqualeader engineer to be called out.

Prior to contacting us, please read the below guide to help establish what the lights may mean.

This will help us to diagnose the problem as quickly as possible and ensure the correct action is taken.

Furthermore, by using this guide, a call-out charge can be avoided if the fault is for example ‘because the user has shut off the water supply’.

Calomax Eclipse 3C5C Eco boiler desktop 5 litre mini

Light on Solid – No flashing

Constant light illuminated means that water supply not connected / is interrupted to boiler.  You will need to check if water is turned on at mains / isolator. See solutions guide ‘point 1 & 2’ below.

PLS NOTE:

If boiler has been turned off at water supply this will put it into “hibernation mode”.
If this has happened, turning the water back on won’t reset the boiler.
You will need to turn the boiler off at the On/Off switch or on the mains supply to reboot the boiler – this will extinguish the light.
Please do these steps before calling an Aqualeader engineer.

Calomax Eclipse Eco Boiler Desktop 10 litre detail

Flashing 1 / 2 /3 flashes per sequence

This indicates scale on the probes. If your boiler is flashing in groups of 1, 2 or 3 flashes then there is an issue with limescale. You will need to call an Aqualeader engineer to help resolve this.  Please make a note of how many times the lights flash prior to contacting us.

Flashing 4 times in a sequence

This means that the internal probes are detecting that the boiler is overfilling.  This can be due to sediment or  limescale (especially in new builds) getting stuck in the inlet solenoid and this causes the machine to stop working.  You will need to call an Aqualeader engineer to help resolve this.

Flashing 9 times – or more….

Thermister has possibly gone out of range – (boiling over 97 degrees) You will need to call an Aqualeader engineer to help resolve this. Suggest check if PCB red LED is illuminated – If ON thermistor is OK.

Problem > No Water Coming Out / Dispensing

Option 1 = Check isolator / water supply

Please make sure the water supply to the machine is turned on. To check this, look at the back of the machine for a small part on the tube which we call a “smurf” it has a blue handle and a white body.

Option 2 = Water Blocker has tripped out’ – and needs re-setting

The ‘Water Blocker’ is an anti-flooding device and acts also as the 1st stage filtering process for the water cooler. Sometimes, if an increase in pressure has been detected it can shut itself off.  Similarly, if large containers or single higher a volume is dispensed the water blocker can think that there is a leak and isolate itself from the mains water supply. To re-set it is very simple. Simply press down the red re-setter button as shown on the image. Press this down firmly and this will reset the water blocker, allowing water to flow back into the machine.

The water block is most often located under the sink where the connection was originally made.

If after checking all of the above you water cooler is still not producing water or chilling – then please contact us via email to help@aqualeader.co.uk – whereby we can instruct an engineer to attend.
Please note – if an engineer attends and the fault is as a result of any of the above then a call out fee of £90 is chargeable.